Refurbishment Of Electronic Dispensing Units in Central Zone
Tender No: RF19909SZ
Active Tender
Closing Date:
2026-09-03
2026-09-03
Tender Overview
- Category
- Mechanical Works & Equipment
- Sector
- Services
- Tender Type
- Services
- Source Name
- PPRA
Location & Dates
Contact & Websites
- Contact Phone
- (021) 9203866-85
Actions
Download Tender Document
Back to All Tenders
Looking for more tenders like this? View all active Mechanical Works & Equipment tenders.
Related Tenders
Supply of Sit-Down Type Electric High Reach Truck (Battery-Operated) at Shershah Depot...
Close: 2026-09-03 Multan, Punjab
Reclamation and Replacement of Damaged 50-KVA Irreparable Transformers and Associated Parts for...
Close: 2026-09-03 Gujranwala, Punjab
Pre-Qualification of Contractors for Civil, Electrical, Mechanical, and Miscellaneous Works at HIT...
Close: 2026-09-04 Taxila, Punjab
Replacement of Damaged Elliptical Tubes of Distribution Transformers (200-KVA and 100-KVA) for...
Close: 2026-09-04 Gujranwala, Punjab
Procurement of DCVG Survey Machine, Metallic Blast Cleaning Abrasives, Gas Meter Components,...
Close: 2026-09-05 Karachi, Sindh
Procurement of DCVG Survey Machine, Metallic Blast Cleaning Abrasives, Gas Meter Components,...
Close: 2026-09-05 Karachi, Sindh
Tender Document
Tender Description
Pakistan State Oil Company Limited (PSO) Karachi invites qualified contractors for the refurbishment of electronic dispensing units in the Central Zone at PSO House, Clifton, Karachi. This procurement covers a comprehensive range of repair, refurbishment, and installation services for dispensing units compatible with TATSUNO, WAYNE, and other models. Items being procured include:
- DU Refurbishment for GDA Tatsuno (100 units)
- Repairing of Keypad (2 units)
- Repairing of CPU (2 units)
- OVP Repair Works (3 units)
- Power supply Repair Works (5 units)
- Power sequence Repair Works (5 units)
- Fabrication of Panel Door (8 units)
- Motor Rewinding Works (5 units)
- Replacement of Motor Clutch (8 units)
- Replacement of Ball bearing in Motor (2 units)
- Pulsar repair works (4 units)
- DU Pumping Assembly Repair Works (10 units)
- DU packing (Polythene bag) (70 units)
- DU paint and graphics (80 units)
- Display Board of DU-Retail Outlet (10 units)
- Display Board of DU-Retail Outlet (40 units)
- Preset Board of DU-Retail Outlet (40 units)
- CPU Board of DU-Retail Outlet (30 units)
- CPU Board of DU-Retail Outlet (2 units)
- Pulsar (ID) DU (15 units)
- Power Supply of DU-Retail Outlet (25 units)
- Power Sequence of DU-Retail Outlet (25 units)
- RELAY 024-23962-000 (20 units)
- OVP Tatsuno GDA new version (30 units)
- Totalizer Tatsuno GDA New Version (120 units)
- 3C Cable Set (JB to Power Supply) DU (5 units)
- Emergency Switch DU (120 units)
- Micro switch Tatsuno GDA new version (120 units)
- Solenoid Valve DU (10 units)
- Diaphragm for solenoid valve (30 units)
- Keypad Sticker of DU-Retail Outlet (80 units)
- Display Sticker of DU-Retail Outlet (80 units)
- D/U Single Electronic Remote (10 units)
- Display Side panel door DU-Retail Outlet (20 units)
- Panel lock set DU (20 units)
- Automatic Nozzle of DU-Retail Outlet (120 units)
- Nozzle Switch Assembly DU (20 units)
- Nozzle boot Tatsuno GDA new version (20 units)
- Swivel of DU-Retail Outlet (120 units)
- Extension pipe Tatsuno GDA NV (120 units)
- Hosepipe of DU-Retail Outlet (120 units)
- Breakaway Coupling of DU-Retail Outlet (120 units)
- Motor 750W of DU-Retail Outlet (15 units)
- Pumping Unit Assembly DU-Retail Outlet (20 units)
- Flow Meter Assembly of DU-Retail Outlet (10 units)
- Adjuster Pulley-Pumping Unit DU (30 units)
- Steel Support For Motor fixing DU (30 units)
- Pipe for Pumping Unit DU (15 units)
- Jain Sheet Pumping Unit DU (50 units)
- Motor Belt DU (30 units)
- Explosion proof Gland DU (10 units)
- Perforated MS Sheet DU (50 units)
- Display Board of DU-Retail Outlet (30 units)
- Preset Board of DU-Retail Outlet (24 units)
- CPU Board of DU-Retail Outlet (15 units)
- Pulsar (Non-ID) DU (8 units)
- Power Supply of DU-Retail Outlet (15 units)
- Power Sequence of DU-Retail Outlet (2 units)
- Motor 750W of DU-Retail Outlet (18 units)
- Solenoid DU (8 units)
- OVP Tatsuno GDA new version (2 units)
- Solenoid Valve DU (10 units)
- Display Sticker of DU-Retail Outlet (30 units)
- Keypad Sticker of DU-Retail Outlet (30 units)
- D/U Single Electronic Remote (8 units)
- Pumping Unit Assembly DU-Retail Outlet (20 units)
- Flow Meter Assembly of DU-Retail Outlet (10 units)
The scope includes isolation, diagnostic checks, repair, replacement of faulty components, calibration, functional testing, installation, and commissioning of all parts. The contractor must provide qualified technicians and labor, ensure compliance with PSO safety and security rules, provide PPEs, and maintain detailed documentation of all work and parts replaced. Delivery of parts must be physical and inspected by PSO engineers. Warranty of one year on all parts is required. The contract includes penalties for delays and non-compliance.
This tender is a valuable opportunity for contractors experienced in electrical and mechanical repair services, especially with PEC relevant categories and FBR/ATL registration. Bidders should prepare their technical and financial bids carefully, ensuring all documentation and compliance requirements are met. The submission deadline is 3rd September 2026. Bidders are advised to coordinate with PSO engineers for site conditions and ensure timely mobilization.
A practical tip for bidders: Ensure your technical team is well-versed with TATSUNO and WAYNE dispensing units and prepare all required documentation in advance to avoid delays during evaluation and inspection phases.